+36 30 487 9066

info@met-industry.hu

Tightness and Leak Testing Device

Leitenberger SLD 01 professional seal and leak detector device. Ideal for testing air conditioning systems and pressure tests.

Description

Additional information

Leitenberger SLD 01 Seal and Leak Detector Device

The Leitenberger SLD 01 seal and leak detector device is a professional tool manufactured in Germany (quality made in Germany), specifically developed for safe and precise pressure testing and leak detection in cooling and air conditioning systems. This mobile solution guarantees documentation accuracy and fast, efficient work on-site.

Key Features and Advantages

The SLD 01 device features several functions that set it apart from competitors, especially in terms of documentation capabilities and flexible application:

  • Safe and Simple Testing: Enables simple and safe seal testing and leak searching for cooling and air conditioning systems.

  • High-Precision Pressure Test: Capable of performing high-precision pressure tests on both the low-pressure and high-pressure sides.

  • Integrated Protocol Printer: With the built-in test protocol printer, test results are immediately printable, ensuring instant documentation of the work.

  • Documentation Integrity: The Real-Time Clock (RTC) function ensures that the date and time cannot be altered, thereby guaranteeing the credibility of the records.

  • Medium-Independent Leak Detection: Possibility for leak detection without the use of contrast agents.

  • Flexible Testing Modes: Suitable for performing tightness pressure tests with nitrogen, as well as leak detection using forming gas.

  • Mobile Applicability: Thanks to the integrated rechargeable battery, the device is fully mobile, ideal for on-site work.

  • Long-Term Recording Capability: The measurement duration for a recorded pressure test can range from a minimum of 10 minutes to a maximum of 24 hours, which is ideal for detecting slow leaks.

Technical Data

The technical parameters of the SLD 01 seal and leak detector form the basis for precise and reliable measurements:

Parameter Value Note
Part number SLD 01 Tightness and leak tester
Nitrogen Test Display 0.1 bar Resolution of pressure change in case of nitrogen test
Leak Detection Test Display 0.01 bar Resolution of pressure change in case of leak detection
Measurement Accuracy 0,5 % Guarantees the reliability of measurements
Maximum Measurement Time is 24 hours Enables long-term stability tests
Minimum Measurement Time 10 minutes The minimum duration of the recorded pressure test
Tápellátás Integrated rechargeable battery Ensures mobility
Protocol Integrated printer Real-time documentation
Time/Date Recording Real-time clock (RTC) Immutable timestamp
Application Areas Cooling and air conditioning systems Pressure test and leak detection

Detailed Function Description

Precise Pressure Measurement and Documentation

The main strength of the SLD 01 device is its ability to record and authenticate measurement data. The 0.5% measurement accuracy ensures that even the smallest pressure fluctuations are recorded precisely.

A real-time clock (RTC) this function is critically important during industrial inspections. This function automatically records the exact time and date of the beginning and end of the test, preventing manipulation, which is essential during quality assurance procedures.

A built-in printer provides immediate feedback on site. After the test is completed, the system automatically generates a record containing the measurement parameters, the pressure curve (if relevant), and the certified timestamps.

Versatile Testing Capabilities

The flexibility of the device allows for managing different maintenance and installation protocols:

  1. Nitrogen Pressure Test: The static pressure test of the systems is performed with nitrogen, where the display shows pressure stability with a resolution of 0.1 bar. This method is used to check the mechanical integrity of the system.

  2. Leak Detection with Forming Gas: For the detection of more complex leaks, where the use of a forming gas (usually a hydrogen-nitrogen mixture) enables extremely sensitive detection. In this mode, the device is capable of identifying even the smallest pressure losses with a resolution of 0.01 bar.

  3. Long-Term Monitoring: The maximum measurement duration of 24 hours allows for monitoring the long-term stability of systems, which is particularly important for systems where the leak manifests only as a slow pressure loss.

Portability and Operation

Mobility was a key consideration during the design of the SLD 01. The integrated rechargeable battery ensures that the instrument is not tethered to a mains power source, allowing it to be used anywhere, even in the most difficult-to-reach locations. This significantly speeds up troubleshooting processes on site.

Accessory Products

In the Leitenberger portfolio, the following useful accessories are also available in connection with the SLD 01 leak tester, which optimize the execution of work:

  • SLD01_LR-AV Drain valve: For depressurizing the system and safely venting the medium.

  • SLD_LR_FW Bottle Trolley: For the safe and easy transport of nitrogen or forming gas cylinders within the work area.

The Leitenberger SLD 01 tightness and leak detector is the ideal choice for every professional seeking a reliable, documentable, and mobile solution for guaranteeing the leak-tightness of refrigeration and air conditioning systems.

Related products

Probe Type 4

Electromechanical temperature controller - QUADRATIC (without bimetal compensation)

Capillary Cooper- Single Cooper Braided

Automotive Thermometer with Lighting for Front Panel Mounting

Hand Operated Dosing Pump with Plexiglass Body

Probe Type 1

Thermometer in Steel Sheet Case for Front Panel Mounting with U-Clamp

Thermometer in Steel Sheet Case for Front Panel Mounting with 3-Hole Front Flange

Thermometer in Steel Sheet Case for Front Panel Mounting with 3-Hole Front Flange